Counter Weight Anchor, Type E, 400 kg
Code: AFA935865
A Type E deadweight anchor that provides an anchorage point on roofs without guard rails or permanent anchorage devices, without damaging the roof surface. It can be dismantled and transported by a single person, since no individual element weighs more than 25 kg. The central extended anchorage eye serves 1 user (140kg) and keeps the connecting lanyard from rubbing on the ground; it can also be used as a fall restraint system.
Prices are sent in a quotation once you submit your cart, adjusted to your quantity and delivery location.
Key features
- Anchorage on roofs without guard rails or permanent anchors, without damaging the roof
- Dismantled and transported by one person, no element over 25 kg
- 12 hot dip galvanized / ED coated top steel plates provide the weight
- 4 rubber coated bottom plates grip the roof surface
- Plates held together by steel cross bars
- Central extended anchorage eye for 1 user (140kg) keeps the lanyard off the ground
- Can be used as a fall restraint system
Technical specifications
| Material | High Strength Alloy Steel |
|---|---|
| Finish | ED coated black |
| Minimum breaking strength | 15 kN (MBS of system) |
| Total weight | 400 kg |
| Weight of individual plates | 25 kg |
| Plates | 12 top steel plates, 4 rubber coated bottom plates |
| Users | 1 (140kg) |
| Standards | EN 795:2012 Type E, TS 16415:2013 Type E |
Used in
Roofs
BUYER'S GUIDE
Selecting a Safe Anchorage Point
The anchorage is the A in the ABCD of fall protection: the point on an independent structure that secures the fall protection device or lanyard. Anchor devices are classified under EN 795:2012 as Type A to E, and every anchor must be strong enough to hold a user in a fall.
- A single anchor point should be rated to at least 12kN for one person; for two people on one anchor the minimum is 21 kN, and no more than two people may use a single anchor.
- Attach at or above shoulder level and as directly overhead as possible, because a low or side anchor increases the fall distance and can cause a pendulum swing into obstacles.
- If unsure of the load rating, consult an engineer; good anchorages are I-beams and other solid fixtures, and you should never anchor to cable hangers, light fixtures or anything not designed for a sudden heavy load.
- Make sure the anchor is approved by the employer or an engineer and check it for damage before connecting; tag out a damaged anchor until a competent person has inspected it.
- Only authorised personnel may install and certify roofing anchors.
Summarised from the manufacturer's catalogue. Selection must follow your site risk assessment and the competent person's judgement.
More in this family
Technical data from the manufacturer's catalogue, page 121. Specifications may change; please confirm with our team before ordering.