SYSTEM ACTIVE · MON–SAT 08.00–17.00 WIB Instagram LinkedIn

Beam Trolley Anchor, Flange Width 80 mm to 250 mm

KStrongBeam TrolleyPPE

Code: AFA930412

EN 795:2012 Type BATEX 2014/34/EUANSI Z359.18-2017 Type A

A movable anchorage point that travels along the length of the beam on which it is mounted, moving with the user. Its adjustable flanges fit different beam sizes and its wheels give very smooth movement over the beam. Highly corrosion resistant and easy to install.

Prices are sent in a quotation once you submit your cart, adjusted to your quantity and delivery location.

Key features

  • Movable anchorage point that travels along the beam with the user
  • Allows continuous safe anchorage across the length of the beam
  • Adjustable flanges for different beam sizes
  • Wheels give extremely smooth movement over the beam
  • Highly corrosion resistant and easy to install

Technical specifications

MaterialAluminum Alloy and Stainless steel
Minimum breaking strength23 kN
Flange width80.0 mm to 250.0 mm
Weight3.9 kg ± 0.01 kg
StandardsEN 795:2012 Type B, ATEX 2014/34/EU, ANSI Z359.18-2017 Type A

BUYER'S GUIDE

Selecting a Safe Anchorage Point

The anchorage is the A in the ABCD of fall protection: the point on an independent structure that secures the fall protection device or lanyard. Anchor devices are classified under EN 795:2012 as Type A to E, and every anchor must be strong enough to hold a user in a fall.

  1. A single anchor point should be rated to at least 12kN for one person; for two people on one anchor the minimum is 21 kN, and no more than two people may use a single anchor.
  2. Attach at or above shoulder level and as directly overhead as possible, because a low or side anchor increases the fall distance and can cause a pendulum swing into obstacles.
  3. If unsure of the load rating, consult an engineer; good anchorages are I-beams and other solid fixtures, and you should never anchor to cable hangers, light fixtures or anything not designed for a sudden heavy load.
  4. Make sure the anchor is approved by the employer or an engineer and check it for damage before connecting; tag out a damaged anchor until a competent person has inspected it.
  5. Only authorised personnel may install and certify roofing anchors.

Summarised from the manufacturer's catalogue. Selection must follow your site risk assessment and the competent person's judgement.

More in this family

Technical data from the manufacturer's catalogue, page 111. Specifications may change; please confirm with our team before ordering.

Cart 0

CTA // READY WHEN YOU ARE

Raise the Safety Standard at Your Site.

The first consultation is free. Tell us what you are dealing with, and our team will map out the approach.